  Datasheet File OCR Text:
  design and specifications are each subject to change without notice. ask factory for the current technical specifications before purchase and/or use. should a safety concern arise regarding this product, please be sure to contact us immediately. built-in sensors notes safety precautions do not use these sensors under any circumstances in which the range of their ratings, environment conditions or other specific ations are exceeded. using the sensors in any way which causes their specifications to be exceeded may generate abnormally high levels of heat, emit smoke, etc., resulting in damage to the circuitry and possibly causing an accident. before connecting a connector, check the pin layout by referring to the connector wiring diagram, specifications diagram, etc., and make sure that the connector is connected properly. take note that mistakes made in connection may cause unforeseen problems in oper ation, generate abnormally high levels of heat, emit smoke, etc., resulting in damage to the circuitry. do not use any motion sensor which has been disassembled or remodeled. protection circuit recommended. the possible failure mode is either open or short of the output transistor. an ecess heat is the cause for short mode failure. for any important and serious application in terms of safety, add protection circuit or any other protection method. ?various safety equipment and safety equipment ?traffic light ?security crime prevention equipment ?equipment concerning control and safety of trains, cars, etc. ?applications such as temperature control using sensor output etc. if it is expected that malfunction of each sensor may cause injury to persons or serious expansion damage, be sure to implement safety measures such as double safety circuit. request for ordering and use the products and specifications listed in this document are subject to change for product improvement, etc. (including specific ation changes and discontinued manufacturing). when examining mass-production design or placing an order for the listed products, please cont act panasonic to make sure that the information listed in this document is up-to-date. if it is expected that malfunction of each sensor may cause injury to persons or serious expansion damage, be sure to implement safety me reference standards : computers, office automation equipment, communications equipment, audio-video products, home electrical appliances, machine tools, personal devices, industrial robots. special standards : transportation equipment (automobiles, trains, ships, etc.), traffic signal equipment, crime and disaster prevention devices, electric power equipment, various safety devices, and medical equipment not directly targeted for life support specified standards : aircr aft equipment, aeronautical and space equipment, seabed relay equipment, nuclear power control systems, and medical equipment, devices and systems for life support. before considering the use of our products under the following conditions, you must contact one of our customer service repres entatives without fail and exchange written specifications. ?when our products are to be used in any of the applications listed for the special standards or specified standards. ?when, even for any of the applications listed for the reference standards, our products may possibly be used beyond the range of the specifications, environment or conditions listed in the document or when you are considering the use of our products in any con ditions or an environment that is not listed in the document. [acceptance inspection] for a purchased or delivered product, please conduct an acceptance inspection promptly with adequate consideration given to the management and maintenance of the product before and during the acceptance inspection. [warranty period] the warranty period of these products is one year after the purchase or delivery to a location designated by your company, unle ss otherwise specified by both parties. [scope of warranty] if a failure or a defect attributable to panasonic is found during the warranty period, we will promptly provide a replacement or a necessary replacement part or change/repair the defective part free of charge at the location of the purchase or delivery. the warranty does not cover a failure or a defect when any of the following applies : (1) caused by specifications, standards, or handling methods, etc. designated by your company. (2) caused by modification of the structure, capabilities, or specifications, etc., in which panasonic is not engaged, carried out after the purchase or delivery. (3) caused by an unforeseen phenomenon that cannot be predicted with the technologies available after the time of the purchase or at the time of concluding the agreement. (4) when the product was used outside the scope of the conditions/environments described in the catalog or specifications. (5) when the product is incorporated in your company's equipment for use, damages that could be avoided if your company's equip ment had industry-standard functions, structures, etc. (6) caused by natural disasters or force majeure. the warranty described here is limited to the purchased or delivered product only and does not cover any consequential damages arising from the failure or defect of the product. [before purchase] the standard prices of the products listed in this catalog do not include consumption tax, delivery, installation & adjustment fees, used product collection fees, etc. the specifications/appearance are subject to change without notice for product improvement. the export of products that fall into the category of strategic goods (or services) require an export (or a service transactio n) license under the foreign exchange and foreign trade law. please contact panasonic for details. for details of the products listed in this catalog, please contact distributors, specialty contractor stores, or panasonic. mar. 2019 00 downloaded from: http:///
design and specifications are each subject to change without notice. ask factory for the current technical specifications before purchase and/or use. should a safety concern arise regarding this product, please be sure to contact us immediately. pressure sensor/ps-a (adp5) preheating with in 60 sec. with in 10 sec. 230 c150 c 446 f302 f main heating temperature time notes mounting use the land of the printed-circuit board on which the sensor is securely fixed. soldering avoid the external thermal influence as the product has a limited thermal capacity due to its compact structure. heat deformation may damage the sensor or deteriorate its performance. use the non-corrosive rosin flux. prevent the flux from entering into the inside of the product as the sensor is exposed to the atmosphere. 1) manual soldering ? raise the temperature of the soldering tip between 260 and 300 c 500 and 572 f (30 w) and solder within 5 seconds. ? the sensor output may vary if the load is applied on the terminal during soldering. ? keep the soldering tip clean. 2) dip soldering (dip terminal) ? keep the temperature of the dip solder tank below 260 c 572 f and solder within 5 seconds. ? to avoid heat deformation, do not perform dip soldering when mounting on the circuit board which has a small thermal capacity. 3) reflow soldering (smd terminal) ? the recommended reflow temperature profile conditions are given below. ? we recommend the screen solder printing method as the method of cream. ? please refer to the recommended pc board specification diagram for the pc board foot pattern. ? self alignment may not always work as expected, therefore, please carefully the position of the terminals and pattern. ? the temperature of the profile is assumed to be a value measured with the printed wiring board of the terminal neighborhood. ? please evaluate solderbility under the actual mounting conditions since welding and deformation of the pressure inlet port may occur due to heat stress depending on equipments or conditions. 4) rework soldering ? complete rework at a time. ? use a flattened soldering tip when performing rework on the solder bridge. do not add the flux. ? keep the soldering tip below the temperature described in the specifications. 5) avoid drop and rough handling as excessive force may deform the terminal and damage soldering characteristics. 6) keep the circuit board warpage within 0.05 mm of the full width of the sensor. 7) after soldering, do not apply stress on the soldered part when cutting or bending the circuit board. 8) prevent human hands or metal pieces from contacting with the sensor terminal. such contact may cause anomalous outlets as the terminal is exposed to the atmosphere. 9) after soldering, prevent chemical agents from adhering to the sensor when applying coating to avoid insulation deterioration of the circuit board. 10 ) please consult us concerning leadfree soldering. wire connection 1) correctly wire as in the connection diagram. reverse connection may damage the product and degrade the performance. 2) do not use idle terminals to prevent damages to the sensor. cleaning ? prevent cleaning liquid from entering the inside of the product as the sensor is exposed to the atmosphere. ? do not perform ultrasonic cleaning in order to prevent damages to the product. environment 1) avoid use and storage in the corrosive gas (organic solvent, sulfurous acid and hydrogen sulfide gases) which negatively affects the product. 2) install the capacitor on the power supply terminal of the sensor and stabilize supply voltage to maintain a superimposed noise resistance. recommended installation is to arrange 0.1 f and 1,000 pf in parallel. before use, check the noise resistance and select/add the optimal capacitor. 3) use surge absorbers as applying the external surge voltage may damage the internal circuit. feb. 2019 01 downloaded from: http:///
design and specifications are each subject to change without notice. ask factory for the current technical specifications before purchase and/or use. should a safety concern arise regarding this product, please be sure to contact us immediately. pressure sensor/ps-a (adp5) 4) malfunction may occur near electric noises from static electricity, lightning, broadcast or amateur radio stations and mobile phones. 5) avoid use in a place where these products come in contact with water as the sensor does not have a splash- proof construction. 6) avoid use in an environment where these products cause dew condensation. when water attached to the sensor chip freezes, the sensor output may be fluctuated or damaged. 7) due to the structure of the pressure sensor chip, the output varies under light. do not expose the sensor chip to light when applying a voltage by using a transparent tube. 8) do not apply high-frequency oscillation, such as ultrasonic waves, to the product. quality check under actual use conditions these specifications are for individual components. before use, carefully check the performance and quality under actual use conditions to enhance stability. other precautions 1) the wrong mounting method and the pressure range may invite the risk of accidents. 2) only applicable pressure medium is dry air. avoid use in the corrosive gas (organic solvent, sulfurous acid and hydrogen sulfide gases) or other mediums containing moisture or foreign substances. such mediums may damage or break the product. 3) the pressure sensor chip is located inside the pressure introduction port. do not insert foreign substances, such as wires, into the port as those substances may damage the chip and close the port. do not block the atmosphere introduction port. 4) use electric power within the rated power range. use beyond the range may damage the product. 5) follow below instructions as static electricity may damage the product: (1) for storage, short the circuit between terminals by using conductive substances or wrap the whole chip with aluminum foil. for storage and transportation, avoid plastic containers which are easily electrified. (2) before use, connect electrified materials on desk and operators to the ground in order to safely discharge static electricity. 6) carefully select and fix tubes, introduction pipes and products based on the working voltage. please contact us for any inquires. 7) after mounding the pressure sensor, prevent the potting agent from entering the pressure and the atmosphere introduction ports when coating the circuit board. use the elastic resin as the heated resin may expand, contract and apply pressure to the sensor. after coating, carefully check if the sensor can be used. feb. 2019 01 downloaded from: http:///
design and specifications are each subject to change without notice. ask factory for the current technical specifications before purchase and/or use. should a safety concern arise regarding this product, please be sure to contact us immediately. pressure sensor/ps-a (adp5) terminal profile note : some part numbers may not be available depending on the combination. please refer to the table of product types on the next page. package/pressure inlet hole s packagelength : 3 mm 0.118 inch , diameter : 3 mm 0.118 inch m packagelength : 5 mm 0.197 inch , diameter : 3 mm 0.118 inch l package (only low pressure type) length : 13.5 mm 0.531 inch , diameter : 5.45 mm 0.215 inch p package (only low pressure type) length : 15.6 mm 0.615 inch , diameter : 5.45 mm 0.215 inch :: : : 01 2 3 base tpe with glass base (standard type) low pressure type without glass base (economy type) :: nil 1 : 1 dip terminal 1 smd terminal : 2 :: : : : : : : : : rated pressure 100 kpa?100 kpa 25 kpa50 kpa 100 kpa200 kpa 500 kpa 1,000 kpa 40 kpa 6 kpa 01 2 3 4 5 6 7 a b6 adp5 (low pressure type) pressure sensor ps-a standard packing : carton : 100 pcs.; case : 1,000 pcs. built-in ampli? er and temperature compensation circuit, no need for circuit design and characteristic adjustment high accuracy and reliability : overall accuracy 1.25% fs (standard), 2.5% fs (low-pressure type) compact size, space-saving : compatible size for ps type (standard/economy, s and m pack ages) rohs compliant pressure sensor built-in ampli? er and compensating circuit package (pressure inlet hole length) part no. standard type standard/economy type low pressure type s package (3 mm 0.118 inch ) m package (5 mm 0.118 inch ) m package (5 mm 0.197 inch ) l package (13.5 mm 0.531 inch ) p package (15.6 mm 0.614 inch ) pressure terminal dip terminal smd terminal dip terminal smd terminal dip terminal dip terminal dip terminal standard type (with glass base) 100 kpa adp5100 adp5200 adp5101 adp5201 CCC ?100 kpa adp5110 adp5210 adp5111 adp5211 CCC 25 kpa adp5120 C adp5121 CCCC 50 kpa adp5130 C adp5131 CCCC 100 kpa adp5140 adp5240 adp5141 adp5241 CCC 200 kpa adp5150 adp5250 adp5151 adp5251 CCC 500 kpa adp5160 adp5260 adp5161 adp5261 CCC 1, 000 kpa adp5170 ADP5270 adp5171 adp5271 CCC economy type (without glass base) 40 kpa CC adp51a11 CCCC low pressure type 6 kpa CCCC adp51b61 adp51b62 adp51b63 industrial use : pressure switches and pneumatic components, compressed air pressure measuring devices medical use : blood pressure meters, oxygen generator and airbeds others : pressure sensing devices for air pressure mediums low-pressure type water level detection for domestic appliances: washing machines and dishwashers air pressure control : cleanrooms and smoking rooms medical applications : breathing pressure measuring devices features ordering information product types typical applications feb. 2019 01 downloaded from: http:///
design and specifications are each subject to change without notice. ask factory for the current technical specifications before purchase and/or use. should a safety concern arise regarding this product, please be sure to contact us immediately. pressure sensor/ps-a (adp5) rating item standard type (with glass base) remarks type of pressure gauge pressure pressure medium air ? 1 rated pressure (kpa) 100 ?100 25 50 100 200 500 1,000 max. applied pressure twice of the rated pressure 1.5 times the rated pressure ambient temperature ?10 c to +60 c 14 f to +140 f (no freezing or condensation) storage temperature ?20 c to +85 c ?4 f to +185 f (no freezing or condensation) drive voltage 50.25 v temperature compensation range 0 c to 50 c 32 f to 122 f offset voltage 2.50.05 0.50.05 v ? 2, 3, 5 rated output voltage 4.50.05 (+when +100kpa) 4.50.05 v ? 2, 3, 5 overall accuracy 1.25 %fs ? 3, 4, 5 current consumption max. 10 ma ? 2, 3 output impedance 15 (typical) ? 2 source current max. 0.2 ma ? 2, 3 sink current max. 2 ma ? 2, 3 item economy type (without glass base) remarks type of pressure gauge pressure pressure medium air ? 1 rated pressure (kpa) 40 max. applied pressure twice of the rated pressure ambient temperature ?5 c to +50 c 23 f to +122 f (no freezing or condensation) storage temperature ?20 c to +70 c ?4 f to +158 f (no freezing or condensation) drive voltage 30.15 v temperature compensation range 5 c to 45 c 41 f to 113 f offset voltage 0.30.09 v ? 2, 3, 5 span voltage 2.40.03 v ? 2, 3, 5 offset voltage temperature characteristics 4.0 %fs ? 3, 4, 5 sensitivity temperature characteristics 1.3 %fs ? 3, 4, 5 current consumption max. 3 ma ? 2 output impedance 20 (typical) ? 2, 3 source current max. 0.15 ma ? 2, 3 sink current max. 1.5 ma ? 2, 3 notes : ? 1 please consult us for pressure media other than air. ? 2 indicates output when temperature is 25 c 77 f . ? 3 indicates output when drive voltage is 5 v. although output ? uctuates due to ? uctuations in the drive voltage, this is not included. ? 4 overall accuracy indicates the accuracy of the offset voltage and rated output voltage at a temperature compensation range of 0 to 50 c 32 to 122 f . ? 5 accuracy is the value at the time of our shipping. please set zero-point calibration function on your products in order to safely use if the offset voltage is shifted. notes : ? 1 please consult us for pressure media other than air. ? 2 indicates output when temperature is 25 c 77 f . ? 3 indicates output when drive voltage is 3 v. although output ? uctuates due to ? uctuations in the drive voltage, this is not included. ? 4 indicates from output value at 25 c 77 f and the change of output at 5 and 45 c 41 to 113 f . ? 5 accuracy is the value at the time of our shipping. please set zero-point calibration function on your products in order to safely use if the offset voltage is shifted. standard type economy type feb. 2019 01 downloaded from: http:///
design and specifications are each subject to change without notice. ask factory for the current technical specifications before purchase and/or use. should a safety concern arise regarding this product, please be sure to contact us immediately. pressure sensor/ps-a (adp5) 0 0 1 2 3 4 5 1000 500 output voltage (v) pressure (kpa) C100 0 1 2 3 4 5 100 0 output voltage (v) pressure (kpa) 0 32 ?1.25 ?1.00 ?0.75 ?0.50 ?0.25 0.00 0.25 0.50 0.75 1.00 1.25 25 77 50 122 accuracy (%fs) temperature (c f ) 0 32 ?1.25 ?1.00 ?0.75 ?0.50 ?0.25 0.00 0.25 0.50 0.75 1.00 1.25 25 77 50 122 accuracy (%fs) temperature (c f )  ?1.25 ?1.00 ?0.75 ?0.50 ?0.25 0.00 0.25 0.50 0.75 1.00 1.25 accuracy (%fs) 0 32 25 77 50 122 temperature (c f )  ?1.25 ?1.00 ?0.75 ?0.50 ?0.25 0.00 0.25 0.50 0.75 1.00 1.25 accuracy (%fs) 0 32 25 77 50 122 temperature (c f ) notes : ? 1 please consult us for pressure media other than air. ? 2 indicates output when drive voltage is 5 v. although output ? uctuates due to ? uctuations in the drive voltage, this is not included. ? 3 overall accuracy indicates the accuracy of the offset voltage and span voltage at temperatures between 0 to 70 c 32 to 158 f (fs=4v) ? 4 the initial offset voltage error is not included in the overall accuracy. low pressure type item economy type (without glass base) remarks type of pressure gauge pressure pressure medium air ? 1 rated pressure (kpa) 6 max. applied pressure twice of the rated pressure ambient temperature 0 c to +70 c 32 f to +158 f (no freezing or condensation) storage temperature ?30 c to +100 c ?22 f to +212 f (no freezing or condensation) drive voltage 50.25 v temperature compensation range 0 c to 70 c 32 f to 158 f offset voltage 0.5 v (typical) ? 2 span voltage 4.0 v (typical) ? 2 overall accuracy 2.5 %fs ? 2, 3, 4 current consumption max. 10 ma output impedance 50 (typical) source current max. 0.2 ma sink current max. 2.0 ma standard type 1.-(1) output voltage adp5170 drive voltage : 5 v temperature : 25 c 77 f applied pressure : 0 to +1,000 kpa 2.-(1) output voltage adp5100 drive voltage : 5 v temperature : 25 c 77 f applied pressure : ?100 to +100 kpa 1.-(2) overall accuracy (offset voltage) adp5170 drive voltage : 5 v temperature : 0 to 50 c 32 to 122 f applied pressure : 0 kpa 2.-(2) overall accuracy (offset voltage) adp5100 drive voltage : 5 v temperature : 0 to 50 c 32 to 122 f applied pressure : 0 kpa 1.-(3) overall accuracy (rated output voltage) adp5170 drive voltage : 5 v temperature : 0 to 50 c 32 to 122 f applied pressure : +1,000 kpa 2.-(3) overall accuracy (rated output voltage) adp5100 drive voltage : 5 v temperature : 0 to 50 c 32 to 122 f applied pressure : +100 kpa reference data feb. 2019 01 downloaded from: http:///
design and specifications are each subject to change without notice. ask factory for the current technical specifications before purchase and/or use. should a safety concern arise regarding this product, please be sure to contact us immediately. pressure sensor/ps-a (adp5) 0.0 0.0 1.0 2.0 3.0 4.0 5.0 3.0 6.0  output voltage (v) applied pressure (kpa) 0 32 10 50 60 140 25 77 70 158 1.000.80 0.60 0.40 0.20 0.00  temperature (c f ) offset voltage (v) 4.504.30 4.10 3.90 3.70 3.50  intial after test span voltage (v)  intial 100h 500h 1.000.80 0.60 0.40 0.20 0.00 offset voltage (v) 4.504.30 4.10 3.90 3.70 3.50  span voltage (v) 0 32 10 50 60 140 25 77 70 158 temperature (c f )  1.000.80 0.60 0.40 0.20 0.00 intial after test offset voltage (v) intial 100h 500h  4.54.3 4.1 3.9 3.7 3.5 span voltage (v)  intial 1.000.80 0.60 0.40 0.20 0.00 after test offset voltage (v) 4.504.30 4.10 3.90 3.70 3.50  intial after test span voltage (v) low pressure type 1 output voltage adp51b61 drive voltage : 5 v temperature : 25 c 77 f applied pressure : 0 to 6 kpa 3 ambient temperature characteristics ambient temperature : 25 c 77 f 0 c 32 f 10 c 50 f 60 c 140 f 70 c 158 f 2 thb (high temperature high humidity bias test) adp51b61 within 85 c 185 f and 85% rh 5 v applied between no.2 (vdd) and no.3 (gnd) applied pressure : 0 kpa 5 vibration test adp51b61 vibration applied : 10 to 55 hz, amplitude : 1.5mm, x, y and z directions, 2 hrs each applied pressure : 0 kpa 4 shock test adp51b61 shock applied : 981 m/s 2 , 3 times in x, y and z directions applied pressure : 0 kpa feb. 2019 01 downloaded from: http:///
design and specifications are each subject to change without notice. ask factory for the current technical specifications before purchase and/or use. should a safety concern arise regarding this product, please be sure to contact us immediately. pressure sensor/ps-a (adp5) 1 cycle (24h) 65 c 149 f 65 c 149 f 25 c 77 f ?10 c 14 f 25 c 77 f 0% rh 95% rh 2.5h 2.5h 2.5h 2.5h 3.5h 1.5h 3h 3h 3h temp.time ???  1.000.80 0.60 0.40 0.20 0.00 intial 10 cyc offset voltage (v) 4.504.30 4.10 3.90 3.70 3.50  intial 10 cyc span voltage (v) 6 temperature/humidity cycle test adp51b61 exposed to 10 cycles in the temperature and humidity conditions given below. applied pressure : 0kpa evaluation test classi? cation tested item tested condition result environmental characteristics storage at high temperature temperature : left in a 85 c 185 f constant temperature bath; time : 100 hrs. passed storage at low temperature temperature : left in a C20 c C4 f constant temperature bath; time : 100 hrs. passed humidity resistance temperature/humidity : left at 40 c 104 f , 90 % rh; time : 100 hrs. passed temperature cycle temperature : C20 c to 85 c C4 f to 185 f ; 1 cycle : 30 min.; times of cycle : 100 passed endurancecharacteristics high temperature/ high humidity operation temperature/humidity : 40 c 104 f , 90% rh; operation times : 10 6 , rated voltage applied passed mechanicalcharacteristics vibration resistance double amplitude : 1.5 mm 0.059 inch ; vibration : 10 to 55 hz; applied vibration direction : x, y, z 3 directions; times : 2 hrs each passed dropping resistance dropping height : 75 cm 29.528 inch ; times : 2 times passed terminal strength pulling strength : 9.8 n {1 kgf}, 10 sec.; bending strength : 4.9 n {0.5 kgf}, left and right 90 1 time passed solderingcharacteristics solderbility temperature : 230 c 446 f ; time : 5 sec. passed heat resistance (dip) temperature : 260 c 500 f ; time : 10 sec. passed items criteria offset voltage rated output voltage variation amount within 2.5%fs of value feb. 2019 01 downloaded from: http:///
design and specifications are each subject to change without notice. ask factory for the current technical specifications before purchase and/or use. should a safety concern arise regarding this product, please be sure to contact us immediately. pressure sensor/ps-a (adp5) 0.5 0.020 6.5 0.256 f 3.0 f 0.118 3.0 0.118 1.8 0.071 r0.2 r0.08 9.5 0.374 7.2max. 7.0max. 0.283max. 0.276max. 4-r0.7 4-r0.028 2.5 2.5 0.98 0.98 7.0 0.276 7.2 0.283 0.25 0.010 nu gnd nu japan vcc nu vout nu nu vcc nu gnd vout f 2.2 f 0.087 pressure inlet hole atmospheric pressure inlet hole vcc  dc 5v  vout 123654 c gnd 7.5 0.295 6- f 0.9 6- f 0.035 2.5 2.5 0.98 0.98 9.5 0.374 1.1 0.043 2.5 2.5 0.098 0.098 1.9 0.075 pressure inlet hole f 2.2 0.5 10.0 0.020 0.394 0.15 0.059 6.5 f 3.0 f 0.118 3.0 0.256 0.118 0.5 2.5 2.5 0.20 0.098 0.098 1.8 0.071 r0.2 r0.008 0.25 0.01 atmospheric pressure inlet hole 7.2max. 7.0max. 4-r0.7 7.0 0.276 7.2 0.283 nu gnd nu vcc nu vout nu nu vcc nu gnd vout japan vcc  dc 5v  vout c gnd 123654 0.283max. 0.276max. f 0.087 4-r0.028 standard type s package (terminal direction : dip terminal pressure inlet hole length : 3 mm 0.118 inch ) adp51 0 standard type s package (terminal direction : smd terminal pressure inlet hole length : 3 mm 0.118 inch ) adp52 0 recommended pc board pattern recommended pc board pattern terminal connection diagram terminal connection diagram terminal no. name 1 vcc (power supply [+]) 2 nu (not usable) 3 vout (output) 4 nu (not usable) 5 nu (not usable) 6 gnd (ground) terminal no. name 1 vcc (power supply [+]) 2 nu (not usable) 3 vout (output) 4 nu (not usable) 5 nu (not usable) 6 gnd (ground) dimensions the cad data of the products with a mark can be downloaded from: http://industrial.panasonic.com/ unit : mm inch general tolerance : 0.3 0.012 unit : mm inch general tolerance : 0.3 0.012 feb. 2019 01 downloaded from: http:///
design and specifications are each subject to change without notice. ask factory for the current technical specifications before purchase and/or use. should a safety concern arise regarding this product, please be sure to contact us immediately. pressure sensor/ps-a (adp5) 5.0 r0.2 8.5 atmospheric pressure inlet hole 0.5 f 3.0 1.8 9.5 7.2max. 7.0max. 4-r0.7 2.5 2.5 7.0 7.2 0.25 gnd nu nu japan vcc nu vout nu nu vcc nu gnd vout pressure inlet hole f 2.2 7.5 6- f 0.9 2.5 2.5 vcc  dc 5v  vout c gnd 123 654 0.283max. 0.276max. 4-r0.028 f 0.087 0.256 0.197 f 0.118 0.071 r0.08 0.020 0.98 0.98 0.276 0.283 0.374 0.010 0.98 0.98 0.295 6- f 0.035 nc nc vcc nc gnd vout atmospheric pressure inlet hole 8.5 5.0 r0.2 0.5 10.0 0.15 f 3.0 0.5 2.5 2.5 1.8 0.25 7.2max. 7.0max. 4-r0.7 7.0 7.2 nc gnd nc vcc nc vout pressure inlet hole f 2.2 japan vcc  dc 5v  vout c gnd 123 654 0.283max. 0.276max. f 0.087 4-r0.028 f 0.118 0.20 0.098 0.098 0.071 0.335 0.197 r0.008 0.276 0.283 0.020 0.394 0.059 0.01 9.5 0.374 1.1 0.043 2.5 2.5 0.098 0.098 1.9 0.075 standard/economy type m package (terminal direction : dip terminal pressure inlet hole length : 5 mm 0.197 inch ) adp51 1/adp51a11 standard type m package (terminal direction : smd terminal pressure inlet hole length : 5 mm 0.197 inch ) adp52 1 recommended pc board pattern recommended pc board pattern terminal connection diagram terminal connection diagram terminal no. name 1 vcc (power supply [+]) 2 nu (not usable) 3 vout (output) 4 nu (not usable) 5 nu (not usable) 6 gnd (ground) terminal no. name 1 vcc (power supply [+]) 2 nu (not usable) 3 vout (output) 4 nu (not usable) 5 nu (not usable) 6 gnd (ground) dimensions the cad data of the products with a mark can be downloaded from: http://industrial.panasonic.com/ unit : mm inch general tolerance : 0.3 0.012 unit : mm inch general tolerance : 0.3 0.012 feb. 2019 01 downloaded from: http:///
design and specifications are each subject to change without notice. ask factory for the current technical specifications before purchase and/or use. should a safety concern arise regarding this product, please be sure to contact us immediately. pressure sensor/ps-a (adp5) 8 23 5 1 4 76 13.97 0.550 2.54 0.100 8- f 1.2 8- f 0.047 atmospheric pressure inlet hole out v gnd cc v nu nunununu pressure inlet hole f 3.0 f 0.118 10.7 0.76 0.030 2.7 0.421 0.106 5.0 0.197 0.25 0.010 14.0 0.551 10.4 0.409 2.54 0.100 p2.54 3=7.62 p0.100 3=0.300 p2.54 3=7.62 p0.100 3=0.300 10.4 0.409 r0.5 r0.020 p/n,lot 1b61 70124 japan 0.01 f1.0 f 13.97 0.550 2.54 0.100 8- f 1.2 8- f 0.047 p2.54 3=7.62 p0.100 3=0.300 8 23 5 1 4 76 pressure inlet hole 19.3 0.76 0.030 2.7 0.760 0.106  13.5   0.535  0.25 0.010 14.0 0.551 10.4 0.409 10.4 0.409 p/n,lot 70124 japan out v gnd cc v nu nunununu f 5.45 f 0.215 c0.3 c0.012 r0.5 r0.020 1b61 0.01 f1.0 f 2.54 0.100 p2.54 3=7.62 p0.100 3=0.300 atmospheric pressure inlet hole japan 120215 1b63 p/n , lot 0.25 0.010 1234 765 14.0 0.551 20.2 3.3 0.795 0.130 10.4 0.409 13.97 0.550 10.4 0.409 0.76 0.030 2.54 0.100 2.54 0.100 f 5.45 f 0.215 f 3.00 f 0.118 5.6 0.220 15.6 0.614 p2.54 3=7.62 p0.100 3=0.300 p2.54 3=7.62 p0.100 3=0.300 out v gnd cc v nu nunununu 8- f 1.2 8- f 0.047 0.01 f1.0 f pressure inlet hole atmospheric pressure inlet hole low pressure type m package (terminal direction : dip terminal, pressure inlet hole length : 5 mm 0.197 inch ) adp51b61 low pressure type p package (terminal direction : dip terminal, pressure inlet hole length : 15.6 mm 0.614 inch ) adp51b63 low pressure type l package (terminal direction : dip terminal, pressure inlet hole length : 13.5 mm 0.531 inch ) adp51b62 recommended pc board pattern (bottom view) recommended pc board pattern (bottom view) recommended pc board pattern (bottom view) terminal connection diagram terminal connection diagram terminal connection diagram terminal no. name 5 nu (not usable) 6 nu (not usable) 7 nu (not usable) 8 nu (not usable) terminal no. name 1 nu (not usable) 2 vcc (power supply [+]) 3 gnd (ground) 4 vout (output) dimensions the cad data of the products with a mark can be downloaded from: http://industrial.panasonic.com/ terminal no. name 5 nu (not usable) 6 nu (not usable) 7 nu (not usable) 8 nu (not usable) terminal no. name 1 nu (not usable) 2 vcc (power supply [+]) 3 gnd (ground) 4 vout (output) terminal no. name 5 nu (not usable) 6 nu (not usable) 7 nu (not usable) 8 nu (not usable) terminal no. name 1 nu (not usable) 2 vcc (power supply [+]) 3 gnd (ground) 4 vout (output) unit : mm inch general tolerance : 0.3 0.012 unit : mm inch general tolerance : 0.3 0.012 unit : mm inch general tolerance : 0.3 0.012 feb. 2019 01 downloaded from: http:///
design and specifications are each subject to change without notice. ask factory for the current technical specifications before purchase and/or use. should a safety concern arise regarding this product, please be sure to contact us immediately. glossary of common terms for pressure sensors d1 d2 rated pressure rated pressure output voltage output voltage 1/2 rated rated no load offsetvoltage fs pressure object this is what can be used to activate the pressure sensor. (the panasonic corporation pressure sensor can be used with gas.) rated pressure the pressure value up to which the specifications of the pressure sensor are guaranteed. maximum applied pressure the maximum pressure that can be applied to the pressure sensor, after which, when the pressure is returned to below the rated pressure range, the specifications of the pressure sensor are guaranteed. temperature compensation range the temperature range across which the specification values of the pressure sensor are guaranteed. drive current (voltage) the supply current (voltage) required to drive a pressure sensor. output span voltage the difference between the rated output voltage and the offset voltage. the output span voltage is also called the full-scale voltage (fs). offset voltage the output voltage of a pressure sensor when no pressure is applied. rated pressure output voltage output voltage when rated pressure is applied. linearity when the pressure is varied from no load to the rated pressure, the linearity is the amount of shift between the straight line that joins the no-load voltage value and the rated pressure voltage value (expressed as the ratio of the amount of shift (d1) at half of the rated pressure value with respect to the full scale voltage (fs)). output hysteresis the ratio of the difference (d2) in the noload output voltages when the pressure is varied from no load to the rated pressure then reduced back to no load, with respect to the full scale voltage (fs). offset voltage temperature characteristic the variation of the offset voltage with changes in ambient temperature. the difference between the offset voltage at the standard temperature and the offset values at the compensation lower limit temperature (low temperature) (d1) and compensation upper limit temperature (high temperature) (d2) are obtained, and the offset voltage temperature characteristic is expressed as the ratio of the larger of these two differences (absolute) with respect to the full scale voltage (fs). explanation of terms feb. 2019 01 downloaded from: http:///
design and specifications are each subject to change without notice. ask factory for the current technical specifications before purchase and/or use. should a safety concern arise regarding this product, please be sure to contact us immediately. glossary of common terms for pressure sensors no load 1 2 no load fs1 fs compensation lower limit temperature no compensation upperlimit temperature standard temperature  fs2  output voltage the bridge resistance isthe resistance of the four resistive elements that make up the bridge expressed as one combined resistance. r 1 r 2 r 4 r 3 temperature sensitivity characteristic the variation of the sensitivity with changes in ambient temperature (variation in full scale (fs)). the difference between the full scale voltage at the standard temperature (fs) and the full scale values at the compensation lower limit temperature (low temperature) (fs1) and compensation upper limit temperature (high temperature) (fs2) are obtained, and the offset voltage temperature characteristic is expressed as the ratio of the larger of these two differences (fs1 - fs and fs2 - fs (absolute)) with respect to the full scale voltage (fs). bridge resistance refers to the resistance value of a piezoresistance formed on a monolithic silicon substrate. for example, the values of the resistances r1 to r4 in the bridge are typically 5 k each. ? when the resistances of the resistive elements r1 to r4 that comprise the bridge are 5 k each, the equivalent composite resistance of the bridge is 5 k (3 k bridges are also available). overall accuracy accuracy of offset voltage and rated pressure output voltage within the temperature compensation range. feb. 2019 01 downloaded from: http:///
if you want to use our products described in this onlin e catalog for applications requiring special qualities or reliability, or for applications where the failure or malfunction of the products may directly jeopardize human life or potentially caus e personal injury (e.g. aircraft and aerospace equipment, traffic and transportat ion equipment, combustion equipment, medical equipment, accident prevention, anti-crime eq uipment, and/or safety equipment), it is necessary to verify whether the specificatio ns of our products fit to such applications. please ensure that you will ask and check with our inquiry desk as to whether the specifications of our products fit to such applications use before you use our products. the quality and performance of our products as described in this online catalog only apply to our products when used in isolation. therefore, please en sure you evaluate and verify our products under the specific circumstances in which our pr oducts are assembled in your own products and in which our products will actually be used. if you use our products in equipment that requires a h igh degree of reliability, regardless of the application, it is recommended that you set up protectio n circuits and redundancy circuits in order to ensure safety of your equipment. the products and product specifications described in this online catalog are subject to change for improvement without prior notice. therefore, pleas e be sure to request and confirm the latest product specifications which explain the specifications of our products in detail, before you finalize the design of your applications, pu rchase, or use our products. the technical information in this online catalog provides example s of our products' typical operations and application circuits. we do not guarantee the non-infringement of third party's intellectual property rights and we do not grant any license, right, or interest in our intellectual property. if any of our products, product specifications and/or technical information in this online catalog is to be exported or provided to non-residents, the laws and regulations of the exporting country, especially with regard to security and ex port control, shall be observed. the switchover date for compliance with the rohs directive /reach regulations varies depending on the part number or series of our products. when you use the inventory of our products for which it is unc lear whether those products are compliant with the rohs directive/reach regulation, please se lect "sales inquiry" in the website inquiry form and contact us. we do not take any responsibility for the use of our products outside the scope of the specifications, descriptions, guidelines and precautions described in this online catalog. guidelines and precautions regarding the described in this online catalog. downloaded from: http:///


▲Up To Search▲   

 